Download pdf addressable fire alarm control panels datasheets. Before you start using the 4100 fire alarm operator s manual, its important to understand the typographic conventions used in this publication. A variety of functional modules are available to meet specific system requirements. The panel serves as an operating panel for one or several defined operation zones. The comprehensive range of detectors, advanced detectors, beam detectors, manual call points, audible and visible devices make the nfs28 one of the most capable nonaddressable systems on the market. Fire control panel detect 3004plus series and accessories.
Addressable fire alarm control panels datasheets tyco. Fire alarm control panel bs420m autrosafe 4 fire detection system. There is danger of explosion if the battery is incorrectly replaced. Analogueaddressable fire panel fx50 technical manual. A fire alarm control panel facp, fire alarm control unit facu, or simply fire alarm panel is the controlling component of a fire alarm system. Pdfdownload brochure the fire alarm control panel solution f1. Control panels shall be assembled and tested in a facility that is accredited to iso9002. The n6000 fire alarm control panel has many intelligent characteristics. Any work carried out on this system must be performed by a competent person who is familiar with this type of system. The fire alarm control panel solution f1 nsc sicherheitstechnik. It activates fire alarm notification appliances horns, strobes, and audio evacuation messages when an initiating point activates. The n6000 control panel with cbe control by event control can manage both alarm paging and gas extinguishing systems. Safety hazard the 4100u cpu card includes a lithium battery.
Selections allow control units to be configured for either standalone or networked fire control operation. Simplex 4100u instruction manual pdf download manualslib. Fx50 control unit has been designed for firedetection systems management and is particularly suitable. It monitors and controls auxiliary building equi pment fan dampers. An automatic fire alarm systemtypically made up of smoke detectors. Include sufficient control panel s, annunciators, manual. With its flexibility, unique design and ability to utilize both intelligent and conventional devices, makes it a very reliable system for life safety use. Contact your local simplex product supplier for details. The combined installation of a fire panel and a loop for evolution detectors allows using a new type of. Also, you will be advised of your right to file a complaint with the fcc if you believe it is necessary.
Bs420 is a complete fire alarm control panel with full operation capabilities. Fire alarm control panel leverages new technology to help deliver higher levels of serviceability, manageability and value over the life cycle of your investment. View and download simplex 4100u instruction manual online. Conventional fire alarm control panel 1pv0 series features large indicators and switches for easy operation digital display with 7 segments leds for identifying the alarm zone and detailed trouble 6 led indicators for other alarms panel buzzer beeps in sweep tone for making it easier to hear available with endofline resistors of 10 k.
The following conventions are used in this publication to identify special names or text. Zone isolated conditions shall be displayed by a yellow led indicator per zone. Gmbh represents an expert developer, fire detection component manufacturer. Fire alarm control panel bs420 autrosafe 4 fire detection system. Infoalarm command center options provide convenient expanded display content. The audio system modules and features listed in this data sheet are both compatible with, and listed for use with 4100u series fire alarm control panels. The solution f1 fire control panel range is a new generation, modular and ultra.
Overview the simplex 4100u fire alarm control panel facp has three general functions. The n6000 connected with a crt display terminal forms a comprehensive and reliable fire alarm. Addressable fire detection and control, basic panel modules and accessories download pdf 41009314, 9315, 9316, 95, 9512, 9352, 9355 4100es facp. An automatic fire alarm systemtypically made up of smoke detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control panel with remote. Dispose of used batteries according to the manufacturers. Fire alarm control panel safety issues there is no need to open this fire alarm during normal operation. It monitors fire alarm initiating points smoke detectors, heat detectors, and pull stations. Es200x and es200xc fire alarm control panels operating instructions. All autrosafe systems must include at least one bs420m panel. Convention meaning bold type indicates words or characters that you type. The lf6200a1 is a distributed intelligent fire alarm control panel with a microprocessor based advanced detection and protection system. A mass storage device that can ensure all of your systems software is archived in your panel.
Its advanced peertopeer, token ring network provides a communications platform for master annunciation, control and information sharing that does not require centralized processing. Note to sort a column of documents, click the arrow next to the column heading. This module allows the host control panel to be selected to function as either the xa loop master controller head end or as a data gathering panel as an intelligent device on the xa loop reporting to a remote master controller. Fire alarm system limitations while a fire alarm system may lower insurance rates, it is not a substitute for fire insurance. Addressable fire alarm control panel silent knight. Zone isolate and deisolate control shall be by a switch per zone. This equipment will operate safely provided it has been installed correctly in compliance with the installation manual. It adopts the use of a multiline lcd screen for ease of viewing of events and controls, rtos real. Designed with efficiency in mind nfs28 series nonaddressable fire alarm control panels offer the ideal solution for smaller installations. Replace only with the same or equivalent type recommended by the manufacturer. F1 panels are compatible to the newest analogue addressable detectors of hochiki.